{"created":"2023-06-19T08:45:34.592550+00:00","id":916,"links":{},"metadata":{"_buckets":{"deposit":"ea3d7c43-27ce-43a9-ad90-6c1d25d1c64b"},"_deposit":{"created_by":3,"id":"916","owners":[3],"pid":{"revision_id":0,"type":"depid","value":"916"},"status":"published"},"_oai":{"id":"oai:ycu.repo.nii.ac.jp:00000916","sets":["4:71:315:318"]},"author_link":["2240","2242","2241","2239"],"item_2_biblio_info_12":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2005-05-31","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"3","bibliographicPageEnd":"156","bibliographicPageStart":"151","bibliographicVolumeNumber":"56","bibliographic_titles":[{"bibliographic_title":"横濱醫學"},{"bibliographic_title":"The Yokohama medical journal","bibliographic_titleLang":"en"}]}]},"item_2_description_11":{"attribute_name":"抄録(英)","attribute_value_mlt":[{"subitem_description":"We studied the differences in latency and amplitude between the laser stimulated visual evoked potentials (VEPs) and the cathode-ray tubes (CRTs) stimulated VEPs to estimate the risk of inducing photosensitive epilepsy by laser displays. Twenty healthy subjects were recruited for the study. Red and blue light stimulations were flashed in 1, 7.5 and 15Hz. The latency of P1, N1, P2 and N2 in 1 Hz stimulation revealed no significant difference by a paired t test between laser and CRT stimulation. The peak-to-peak amplitude was significantly smaller with red or blue laser stimulation than with red or blue CRT stimulation, for PI-N1 and N1-P2 at 7.5Hz stimulation, and for N1-P2 and P2-N2 at 15Hz stimulation. We therefore postulate that laser does not produce more excitability to occipital cerebral cortex than CRT does. There was no evidence to say that laser stimulation is more dangerous as the risk of inducing photosensitive epilepsy than conventional CRT stimulation.","subitem_description_type":"Other"}]},"item_2_description_15":{"attribute_name":"表示順","attribute_value_mlt":[{"subitem_description":"3","subitem_description_type":"Other"}]},"item_2_description_16":{"attribute_name":"アクセション番号","attribute_value_mlt":[{"subitem_description":"KJ00004192683","subitem_description_type":"Other"}]},"item_2_description_8":{"attribute_name":"記事種別(日)","attribute_value_mlt":[{"subitem_description":"原著","subitem_description_type":"Other"}]},"item_2_description_9":{"attribute_name":"記事種別(英)","attribute_value_mlt":[{"subitem_description":"ORIGINAL ARTICLE","subitem_description_type":"Other"}]},"item_2_source_id_1":{"attribute_name":"雑誌書誌ID","attribute_value_mlt":[{"subitem_source_identifier":"AN00246369","subitem_source_identifier_type":"NCID"}]},"item_2_source_id_19":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"03727726","subitem_source_identifier_type":"ISSN"}]},"item_2_text_7":{"attribute_name":"著者所属(英)","attribute_value_mlt":[{"subitem_text_language":"en","subitem_text_value":"Department of Neurology, Yokohama City University Graduate School of Medicine, Yokohama:Department of Neurology, Fujisawa City Hospital, Fujisawa"},{"subitem_text_language":"en","subitem_text_value":"Department of Neurology, Yokohama City University Graduate School of Medicine, Yokohama"},{"subitem_text_language":"en","subitem_text_value":"Department of Neurology, Yokohama City University Graduate School of Medicine, Yokohama"},{"subitem_text_language":"en","subitem_text_value":"Medical Risk Analyzing Group, QSGHO, Sony, inc."}]},"item_2_title_3":{"attribute_name":"論文名よみ","attribute_value_mlt":[{"subitem_title":"Comparison of Visual Evoked Potential Components between Laser and Cathod-Ray Tubes Stimulation in Healthy Human Subjects"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Miyasaki, Hidetake","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"2239","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Hakii, Yasuhito","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"2240","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Kuroiwa, Yoshiyuki","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"2241","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Oyamada, Hiroshi","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"2242","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2017-04-21"}],"displaytype":"detail","filename":"KJ00004192683.pdf","filesize":[{"value":"496.4 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"KJ00004192683.pdf","url":"https://ycu.repo.nii.ac.jp/record/916/files/KJ00004192683.pdf"},"version_id":"30d17811-d56d-407a-9163-708dca0d7c34"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"Amplitude","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Cathod-Ray Tubes","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Environmental Hazards","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Laser","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Latency","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Visual Evoked Potentials","subitem_subject_language":"en","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Comparison of Visual Evoked Potential Components between Laser and Cathod-Ray Tubes Stimulation in Healthy Human Subjects","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Comparison of Visual Evoked Potential Components between Laser and Cathod-Ray Tubes Stimulation in Healthy Human Subjects","subitem_title_language":"en"}]},"item_type_id":"2","owner":"3","path":["318"],"pubdate":{"attribute_name":"公開日","attribute_value":"2017-04-21"},"publish_date":"2017-04-21","publish_status":"0","recid":"916","relation_version_is_last":true,"title":["Comparison of Visual Evoked Potential Components between Laser and Cathod-Ray Tubes Stimulation in Healthy Human Subjects"],"weko_creator_id":"3","weko_shared_id":-1},"updated":"2023-06-19T09:58:41.954989+00:00"}